XLS40 Enclosed Linear LED Batten Light

A clip-retained cover encloses the XLS40 linear LED body. Compare its 1205 mm length, 40 W light source, 4000 K or 6500 K order choices and the electrical, mounting and delivery details in a batten-light quote.

Fixture body
XLS40 enclosed linear LED batten; white ABS + PC assembly.
Light color / CCT
XLS40, 40 W integrated LED, 4000 K, white ABS + PC body; nominal 4000 lm and CRI 80.
Overall dimensions
1205 L × 83 W × 75 H mm. Fixing centers and cable-entry dimensions follow the actual offered assembly.
Light color / CCT 4000 K

XLS40 Enclosed Body & Integrated LED Source

A 1205 mm Enclosed Linear Body

The XLS40 body measures 1205 mm long, 83 mm wide and 75 mm high. Its elongated enclosure carries a pale light-transmitting cover held by perimeter retainers. Both ends are closed around the fixture body, giving it a different construction from an exposed LED tube or a spotlight fitted to a track rail.

A 40 W Integrated LED Light Source

The fixture uses an integrated LED source, with the light source included in the model schedule. Nominal input power is 40 W and nominal luminous flux is 4000 lm. These figures describe the complete listed fixture; they are not a replaceable fluorescent-tube wattage or a guarantee of illuminance at a work surface.

White ABS and PC Construction

The selected model combines ABS and PC materials in a white assembly. The cover, enclosure edges and accessible retainers are coordinated with the final mounting and cable-entry detail. The model carries a listed IP65 code; cable entries, connections and the completed installation remain part of the project specification.

Complete XLS40 enclosed linear batten with a pale cover, perimeter retainers and both closed ends

4000 K or 6500 K Batten-Light Selection

Actual CCT alternatives on the same white 40 W enclosure

4000 K for a Neutral-White Lighting Schedule

The 4000 K option provides a neutral-white color-temperature direction for the batten schedule. It retains the same 40 W fixture body and white exterior. The order keeps this CCT reference on each room or circuit line so adjacent fixtures use the intended color selection.

6500 K for a Cooler Daylight Direction

The 6500 K option shifts the light color toward a cooler daylight appearance without changing the enclosure size. It is chosen per fixture when ordering, with no on-site switching between color temperatures assumed. A mixed-CCT project records the quantity and location of each choice.

One Body Finish, Separate Light-Color Choices

Both CCT selections use the same white exterior and ABS/PC material. Nominal color rendering is CRI 80, with 4000 lm listed for the model. An accepted energized sample can establish the intended color appearance; neither color card nor lumen total supplies a beam file or a work-plane lighting calculation.

XLS40 Dimensions & Electrical Schedule

Fixture bodyXLS40 enclosed linear LED batten; white ABS + PC assembly.
Color-temperature selectionXLS40, 40 W integrated LED, 4000 K, white ABS + PC body; nominal 4000 lm and CRI 80.
Light-source scheduleIntegrated LED included; 40 W nominal input; 4000 lm nominal flux; CRI 80.
Overall dimensions1205 L × 83 W × 75 H mm. Fixing centers and cable-entry dimensions follow the actual offered assembly.
Electrical rating110–220 V listed supply; actual voltage version, frequency, driver/control and connection requirements recorded for the destination.
Enclosure and installationListed IP65. Complete cable entries, connections, fixing details and cover access are coordinated with the project.
SupplyFixtures by CCT and quantity; named mounting/connection parts, sample, documents, packing, freight and installation, each scheduled.
Minimum orderQuoted per model at your project quantity. Where a factory model has a production minimum, the quotation states it; small quantities can ship with the rest of your project in one container.
Standards & certificatesMatched to the ordered model: tell us the standards or certificates your market or project requires, and we confirm in writing which documents are available for this configuration before you order.
1205 mm overall length, 83 mm width and 75 mm height; no fixing-center or cable-entry dimensions inferred Open product drawing ↗

Fixture Rows, Electrical Version & Mounting Access

1205 mm Body Length and Room Setout

The lighting plan locates the complete 1205 × 83 mm footprint, allowing access around the 75 mm-high body and its cover retainers. Row spacing and mounting height follow the room geometry and required light levels.

The 110–220 V Electrical Version

The rated voltage is 110–220 V. Our order confirmation identifies the actual supply version, local frequency and connection requirements for the destination. Driver, control and wiring details are matched to that version, and any dimmer or emergency arrangement is confirmed as an option.

Fixing Points, Cable Entry and Service Access

The mounting schedule identifies the actual fixing points, cable-entry position and any required support parts. Fixing centers and entry dimensions follow the offered assembly, independent of the overall body length. Cover access and the condition of the complete installed enclosure remain available after the fixture is mounted.

XLS40 Batten-Light Price Factors & Supply

Fixture Quantity and CCT Allocation

The fixture line states XLS40, 40 W, the chosen CCT and quantity. A project using both 4000 K and 6500 K has separate quantity lines under the same model. The electrical version and destination remain attached to those lines.

Mounting and Connection Parts

Brackets, fixing parts, cable-entry fittings and any specified connection accessories are named individually when included. Field wiring and the supporting surface belong to the installation. The quote lists each included part and its quantity with the fixture line.

Control, Emergency and Documentation Requirements

Dimming, emergency operation, sensors and special control interfaces are separate requirements with their own supported driver or fixture version. Required conformity documents identify the actual supplied assembly and destination. A standard model specification is not a substitute for project-specific approval.

Samples, Packing and Project Delivery

An energized sample, fixture labels and any agreed documentation are scheduled with the order. Packed dimensions, carton quantities and actual shipment weight support the freight plan. MOQ, production timing, freight and installation responsibilities are confirmed for the final quantity and electrical version.

XLS40 Batten-Light Quote Schedule

Fixtures
XLS40, 40 W, CCT allocation, electrical version and quantities.
Mounting and wiring
Named fixing, support and connection parts; field wiring and labor stated as site work.
Controls and documents
Any supported control/emergency version, energized sample and required assembly-specific documents.
Packing and freight
Fixture labels, carton data, actual shipment weight, destination and delivery responsibilities.

XLS40 Linear LED Batten FAQs

Is XLS40 a complete luminaire or a replacement LED tube?

It is an enclosed integrated-LED batten, with the light source included. Its complete body is 1205 × 83 × 75 mm and the listed input is 40 W.

Are 4000 K and 6500 K selectable on the same installed fixture?

Order the required CCT version: 4000 K or 6500 K. The schedule records the temperature, quantity and room or circuit for each line. Adjustable color control is a separate project requirement with its own supported driver or fixture configuration.

Does 4000 lm determine how many fixtures a room needs?

No. It is the model’s nominal lumen figure; work-plane lux comes from a lighting calculation. Fixture count and spacing depend on room size, mounting height, surface reflectance and the actual light distribution, and the calculation uses the offered fixture’s photometric information when available.

What voltage should be shown on the purchase order?

Record the actual site supply and destination. The rated voltage is 110–220 V, while the supplied electrical version, frequency, driver and connection details are identified for the order. Compatibility with a dimmer or emergency system is not inferred from that voltage notation.

Does the IP65 rating cover the installed light?

The IP65 housing is sealed against dust and water jets. Using IP-rated cable glands and connectors at installation keeps the complete fitting at IP65, and we can include matching glands in the order.

Are mounting parts, dimming and emergency operation included?

No. The quote names the mounting and connection parts actually included. Dimming, sensors and emergency operation require a supported version and their own quote line. Field wiring, installation labor, packing and freight are itemized, keeping the fixture body distinct from a complete installed lighting system.

Request an XLS40 Batten-Light Quote

Complete XLS40 enclosed linear batten with a pale cover, perimeter retainers and both closed ends
XLS40 Enclosed Linear LED Batten Light4000 K
sales@novarmia.com
XLS40 Enclosed Linear LED Batten LightRequest a Quote