Outdoor LED Flood Light with a Die-Cast Aluminum Housing

This outdoor LED flood light uses a die-cast aluminum housing for an area-lighting fixture. Review the head selection, optional photocell, mounting interface and electrical components that define the quoted lighting package.

Housing
LED flood head
Fixture package
Selected die-cast aluminum LED flood-head design: 100 W input-power target, 4000 K CCT target and nominal 120° wide distribution, on/off control; driver, photometry and IP65 evidence required for supplied head
Design input power
100 W
Fixture package 100 W / 4000 K / 120° target / on-off

100 W Flood-Head Design, Aluminum Housing & Wide Distribution

Die-Cast Aluminum Housing

The selected flood-head design retains the die-cast aluminum housing from the offered family. The procurement specification selects 100 W luminaire input power and a 4000 K LED color-temperature target. The actual proposed head and driver are identified against those requirements before the lighting layout is released.

Broad-Area Lighting & Individual Head Aiming

The selected optical requirement is a nominal 120° full-angle wide distribution, defined between the 50% center-beam intensity directions in the principal planes. Head aiming, mounting height and quantity follow the actual photometric file. Multiple heads, a cross-arm and a pole are each counted on the order when required.

Optional Photocell Sensor

The base control is simple on/off switching. A photocell remains an optional component, matched to the driver and switching circuit. The selected electrical requirement is a 220–240 V AC, 50/60 Hz driver package; a different destination supply receives a revised driver and connection schedule.

Two rectangular multi-lens LED flood heads mounted on an outdoor cross-arm

Flood-Light Housing Finish & Optical Face

Two rectangular multi-lens LED flood heads mounted on an outdoor cross-arm

Housing Surface & Mounting Appearance

Black-finished die-cast aluminum is the selected housing direction. The quoted head identifies the coating, optical cover and mounting yoke. Corrosion, impact and outdoor-enclosure documents belong to the actual assembly and are not inferred from the black finish.

Optical Face, Aiming & Glare-Control Selection

The selected color target is 4000 K. Nominal 120° wide distribution is an optical procurement requirement. The final head’s photometric file supplies the distribution used for aiming and site calculations.

Selected Flood-Head Power, Optics & Acceptance Requirements

Fixture typeOutdoor LED flood head with a die-cast aluminum housing
Head & control selectionSelected die-cast aluminum LED flood-head design: 100 W input-power target, 4000 K CCT target and nominal 120° wide distribution, on/off control; driver, photometry and IP65 evidence required for supplied head
Lighting selectionSelected design targets: 100 W luminaire input power, 4000 K CCT and nominal 120° full-angle wide distribution; final output/distribution from matched photometry
Optional controlOn/off switching in base package; compatible photocell when selected as an option
Electrical specificationSelected driver requirement: 220–240 V AC, 50/60 Hz; actual driver, earthing/insulation arrangement and connection details required for proposed head
Mounting interfacesHead dimensions/weight, actual bracket, aiming arrangement, support/fixing design and any pole or arm supplied as an extra
Documentation & supplyIP65 under IEC 60529 procurement acceptance requirement; model-matched enclosure, electrical and photometric documents required
Minimum orderQuoted per model at your project quantity. Where a factory model has a production minimum, the quotation states it; small quantities can ship with the rest of your project in one container.
Standards & certificatesMatched to the ordered model: tell us the standards or certificates your market or project requires, and we confirm in writing which documents are available for this configuration before you order.
Design drawing for 100W4000K flood head with nominal 120degree full-angle target, 220–240VAC50/60Hz input requirement and model-matched IP65 acceptance evidence Open floodlight specification diagram ↗

Flood-Light Position, Mounting & Control Interfaces

Fixture Position & Lighting Requirement

The selected head has 100 W input-power, 4000 K and nominal 120° wide-distribution targets. Actual lumens, intensity distribution, head dimensions and mass come from the proposed assembly’s documents. A lighting calculation uses that photometry with the mounting height and illuminated area.

Mounting Surface & Supporting Structure

The head-to-support connection is coordinated with the selected bracket, mounting surface and actual fixing design. A wall, pole or arm is a separate support selection. Head weight, permitted aiming and attachment details are confirmed for the quoted fixture and support.

Supply, Driver & Photocell Interface

Supply voltage and frequency, driver selection, switching and any photocell are identified as a compatible electrical package. Cable routing and connection points follow the actual fixture instructions and site design. Wiring, power distribution and electrical installation are quoted as site work.

LED Flood-Head Quote & Electrical Supply

Actual Head & Output Selection

The base quotation is per selected 100 W flood head against the 4000 K and nominal 120° optical requirements. The head reference, driver and required technical documents are identified; poles, cross-arms and spare heads have separate quantities.

Photocell & Control Components

An optional photocell and any related switching parts are separate selections. Their compatibility and operating behavior are recorded with the driver and supply.

Mounting Parts & Test Reports

The actual bracket, attachment components and any supplied pole or arm are named individually. Model-matched enclosure, electrical and photometric documents are required for acceptance against the selected flood-head specification.

Packing, Delivery & Site Electrical Work

Packing and freight follow the fixture quantities and destination. Site supports, wiring, power distribution, lifting and installation labor have their own stated responsibilities. The quote distinguishes supplied lighting components from the installed lighting system. Tell us the rooms and quantities and we will put this on one quote with everything else you are ordering, and show you what fits in a container.

Outdoor Flood-Light Supply Schedule

LED fixture
Die-cast aluminum head; selected 100 W input-power, 4000 K and nominal 120° optical targets; proposed head reference and photometry
Controls
220–240 V AC, 50/60 Hz driver requirement; on/off base control, with any compatible photocell itemized as an option
Mounting & documentation
Specified bracket/support parts and fixture test reports
Shipment & site work
Packing and freight; poles/arms, wiring, power distribution, lifting and installation each identified

Outdoor LED Flood-Light FAQs

Which power, color temperature and beam are specified?

The selected procurement design is a 100 W LED flood head with a 4000 K CCT target and nominal 120° wide distribution. These are requirements for the proposed assembly. Lumen output, actual intensity distribution and dimensions must come from its matching technical data.

Is a photocell included?

The base package is on/off switching. A photocell can be added as a separate compatible control item. The quotation names its switching behavior, connection and driver compatibility.

What does the IP65 requirement cover?

IP65 under IEC 60529 is the selected acceptance requirement for the complete head. Matching enclosure documentation must identify the complete head supplied against that requirement. Site cable joints and connection enclosures have separate exposure requirements.

What electrical input is selected?

The selected driver requirement is 220–240 V AC, 50/60 Hz. The quoted driver and complete electrical assembly must match the project supply and local requirements. A 120 V or other supply needs its own matched package.

How is flood-head spacing determined?

No fixed spacing or illuminated area follows from 100 W input power or nominal 120° distribution. Actual photometry, mounting height, tilt and the required light levels establish the lighting plan. The final proposed head needs a matching photometric file.

Does the flood-head package include the pole or arm?

The product image shows a multi-head support arrangement, while the base quotation is per flood head. Poles, cross-arms, mounting hardware, site cabling, foundations and installation are named and priced line by line.

Request an Outdoor LED Flood-Light Quote

Two rectangular multi-lens LED flood heads mounted on an outdoor cross-arm
Outdoor LED Flood Light with a Die-Cast Aluminum Housing100 W / 4000 K / 120° target / on-off
sales@novarmia.com
Outdoor LED Flood Light with a Die-Cast Aluminum HousingOutdoor LED Flood Light with a Die-Cast Aluminum Housing