Aluminum Reducer Strips for Unequal Floor Levels

Satin-silver aluminum reducer strips with a 60 mm inclined cover and concealed fixing track. Compare profiles for 3, 6 and 9 mm finished-floor level differences, using the section drawing to coordinate the joint recess and track seating.

Cover width
60 mm inclined cover.
Finished-floor level difference
60 mm-wide inclined aluminum cover for a 3 mm finished-level difference; 1.5 mm nominal cover thickness and matched concealed fixing track.
Nominal cover thickness
1.5 mm aluminum.
Finished-floor level difference 6 mm Level Difference

Inclined Aluminum Reducer & Concealed Fixing Track

60 mm Inclined Cover

The cover bridges a small difference between two finished-floor levels with a continuous inclined face. Its 60 mm width overlaps the adjoining surfaces, while the eased lips define the two exposed edges.

Central Clip & Concealed Track

A central underside stem engages a separate fixing track within the joint recess. The selected track is 18 mm wide and 10 mm high. Cover and track are supplied as a matched profile set for the chosen level difference.

3, 6 or 9 mm Level Profiles

Three profile choices use the same 60 mm cover width. Each is specified for its 3, 6 or 9 mm finished-floor rise, with the 6 mm version as the default section. The order identifies the required rise on each opening or floor-joint line.

Satin-silver inclined aluminum reducer bar and short matching section showing a central clip stem inside a concealed fixing track

Satin Metal Cover, Edge Lips & Level Profiles

Reducer profile schedule describing the satin-silver inclined aluminum cover, central clip stem and concealed matching track for three floor-level differences

Satin-Silver Aluminum Face

The cover face has a satin-silver aluminum finish requirement. The order reference records the sheen, brushed direction and exposed lips together so adjoining lengths share the same metal appearance.

1.5 mm Nominal Cover

The cover schedule uses 1.5 mm nominal metal thickness. The inclined face and edge lips are coordinated with the matched clip stem, keeping the exposed profile and hidden fixing connection in one section.

Matched Track Components

The concealed aluminum track follows the selected cover length and profile code. Track seating and fastener positions are detailed for the supporting substrate within the joint recess.

Reducer Width, Length & Floor-Level Choices

Cover width60 mm inclined cover.
Level difference60 mm-wide inclined aluminum cover for a 3 mm finished-level difference; 1.5 mm nominal cover thickness and matched concealed fixing track.
Bar length2700 mm cover and matched fixing-track length basis.
Nominal cover thickness1.5 mm aluminum.
Fixing track18 W × 10 H mm concealed aluminum track with central clip engagement.
Joint recess20 mm clear width and 12 mm depth below the lower finished-floor datum.
Face finishSatin-silver aluminum with eased exposed lips.
Cut scheduleOpening references, finished lengths, 3/6/9 mm rise codes and substrate fixing detail.
60 mm reducer cross section for 6 mm floor-level rise, showing an 18 by 10 mm hidden track in a 20 mm-wide by 12 mm-deep recess Open product drawing ↗

Finished-Floor Datums, Joint Recess & Track Seating

Measure the Finished-Level Rise

The rise is the vertical difference between the completed floor surfaces. Select the 3, 6 or 9 mm profile from those finished datums, then record the adjoining floor materials and the required reducer length.

Reserve the Joint Recess

The selected section reserves a 20 mm clear-width recess with 12 mm depth below the lower finished floor. That space receives the 18 × 10 mm track and its fixing detail while the cover overlaps the adjoining finishes.

Schedule Cuts & End Conditions

Standard bar length is 2700 mm. The joint schedule lists finished cut lengths, opening references, ends and any changes in direction, with each cut assigned to the appropriate rise code and matching track.

Reducer Bars, Fixing Tracks & Cut-Length Cost

Cover & Track Lengths

The quotation lists the inclined cover and matched fixing track by length and level code. The cut schedule connects those quantities to openings and floor joints, including the selected 3, 6 or 9 mm rise.

Metal Finish & Exposed Edges

The finish covers the satin-silver face and exposed edge lips. The sample section records sheen, metal thickness requirement and the appearance where the cover meets both floor finishes.

Track Fixing & Substrate

The joint detail identifies the substrate and the track-fastening method. Recess preparation and fixing components are listed as their own lines next to the cover/track extrusion lengths.

Cut Labels & Protection

Protective packing keeps the satin face and lips apart in transit. Labels identify opening, cut length, rise code and matched track, supporting an orderly room-by-room installation sequence.

Reducer Cover & Track Supply Schedule

Profiles
60 mm cover and matched track by rise code and length.
Cuts
Finished opening lengths and end-condition schedule.
Fixing
Recess preparation and substrate-specific track fixing items.
Packing
Protected metal faces with opening, rise and cut-length labels.

Unequal-Level Aluminum Reducer FAQs

What defines the 3, 6 and 9 mm options?

They are the vertical differences between the two finished-floor surfaces. Each option uses a matched inclined cover and track profile for that rise, with 60 mm cover width.

What is the standard bar length?

The length basis is 2700 mm. The project cut schedule lists the finished cover and matching track lengths for each opening or floor joint.

How is the cover fixed?

A central underside clip engages a concealed aluminum track within the joint recess. The track-fastening detail is specified for the actual supporting substrate.

What recess does the selected section use?

It reserves 20 mm clear width and 12 mm depth below the lower finished floor. The concealed track is 18 mm wide and 10 mm high.

Where is the level difference measured?

Measure vertically between the completed floor surfaces. The reducer schedule uses those datums together with the floor-material references and required cut length.

How are the different profiles identified for installation?

Labels carry the opening reference, finished cut length and 3/6/9 mm rise code. The matching track uses the same code, with protective packing around the satin face.

Request an Aluminum Reducer Quote

Satin-silver inclined aluminum reducer bar and short matching section showing a central clip stem inside a concealed fixing track
Aluminum Reducer Strips for Unequal Floor Levels6 mm Level Difference
sales@novarmia.com